<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-01 23-00-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 57 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.0 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19152 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,2 dBr 1,78 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Cosi Fan Tutte: Trio (Mozart) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/11/01 22.59.40 Total samples: 19152 Equivalent time: 0:15:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 2,9 dBr MIN: -1,2 dBr AVE: 1,78 dBr % above 12,2 dBr: 0,0 Last value: 2,7 dBr (2025/11/01 22.59.39) 22.46 22.48 22.50 22.52 22.54 22.56 22.58 -2 -1 0 1 2 3 Pm [dBr]